WATCH MATERIAL INTERCHANGE LIST
 710/241
 PALLET FORK & ARBOR S/S
 710/ETA 1080
 Price Each $  30.30
 
 AS 1430  DIRECT CENTER SECOND
 AS 1441  DATE-DIRECT CENTER SECOND
 AS 1442  CALENDAR-DIRECT CENTER SECOND
 AS 1485  DIRECT CENTER SECOND-RESERVE INDICATOR
 BEN BH  DIRECT CENTER SECOND
 BEN BK  DIRECT CENTER SECOND
 BEN CF  DIRECT CENTER SECOND-AUTOMATIC
 BEN DF  DIRECT CENTER SECOND - ALARM=LNG 1243
 BEN DL  DIRECT CENTER SECOND
 BEN DR  DSS OFFSET CENTER
 BEN DR2F2  18000 BPH DSS HACK CALD
 BEN DR2F5  18000 BPH DSS CALD KIF
 BEN DX  DIRECT CENTER SECOND-ALARM
 BEN EG  AUTOMATIC-DIRECT CENTER SECOND-OFFSET
 BEN ER  DIRECT CENTER SECOND - SELF REGULATOR
 BLF 11G  18,00 BPH DSS AUTO SHOCK
 BLF 11K  DIRECT CENTER SECOND KIF
 ELG 679  DIRECT CENTER SECOND
 ELG 829  CALENDAR-DIRECT CENTER SECOND
 ETA 1080  DIRECT CENTER SECOND
 ETA 1080-1081  DSS
 ETA 1081  DIRECT CENTER SECOND
 ETA 1093  CALENDAR-DIRECT CENTER SECOND
 ETA 1152  DIRECT CENTER SECOND
 ETA 1153  DIRECT CENTER SECOND
 ETA 1177  RUBY SHOCK DIRECT CENTER SECOND
 ETA 1256  AUTO DSS
 ETA 1258  AUTOMATIC - CALENDAR - DIRECT CENTER
 ETA 2354  DSS OFFSET CENTER WHL
 ETA 2370  DSS
 ETA 2372  DIRECT CENTER SECOND-OFFSET CENTER
 ETA 2373  DSS CALENDAR
 ETA 2375  AUTO DSS
 ETA 2378  AUTOMATIC-CALENDAR-DIRECT CENTER
 GP 45  AUTOMATIC-DIRECT CENTER SECOND
 GP 47  AUTOMATIC-DIRECT CENTER SECOND
 GP 48  DIRECT CENTER SECOND-STOP
 GRU 445SS  
 HAM 571  
 HAM 660  AUTO DSS
 HAM 671  DIRECT CENTER SECOND *
 HAM 672  AUTOMATIC DIRECT CENTER SECOND
 HAM 675  ALARM DIRECT CENTER SECOND
 HAM 871  =ETA 1080
 ILL 651  AUTOMATIC-DIRECT CENTER SECOND
 ILL 652  AUTOMATIC-RESERVE INDICATOR-DIRECT
 ILL 654  DIRECT CENTER SECOND
 LIP R107.1  AUTOMATIC-CALENDAR-DIRECT CENTER SECOND
 LNG 1004-OLD  SWEEP SECOND
 LNG 1022  
 LNG 1027  DIRECT CENTER SECOND
 LNG 1037  AUTO DSS
 LNG 1054  SWEEP SECOND
 LNG 1056  DIRECT CENTER CALENDAR
 LNG 1064  DIRECT CENTER SECOND
 LNG 1106-OLD  
 LNG 1127  DIRECT CENTER SECOND
 LNG 1154  SWEEP SECOND
 LNG 1241  ALARM-DIRECT CENTER SECOND-OFF SET CENTER
 LNG 1243  ALARM-DIRECT CENTER SECOND-OFF SET CENTER WHEEL
 LNG 1244  DIRECT CENTER SECOND-ALARM
 MAR 540  FOR SWEEP USE MARVIN 565
 MAR 565  SWEEP SECOND
 MST 1105  DIRECT CENTER SECOND
 PIE 105  FOR SWEEP SECOND USE PIERCE 105 SWEEP
 PIE 105(SWEEP)  DIRECT CENTER SECOND
 PIE 711  
 PIE 812  
 SAN (HSF) 1177  DIRECT CENTER SECOND-RUBY-SHOCK
 TUD 1156  DSS-18000 BPH
 TUD 1182  DIRECT CENTER SECOND-KIF
 VEN 220  DIRECT CENTER SECOND
 VEN 221  DIRECT CENTER SECOND CALENDAR W/UNIT & TENS DISK
 VEN 222  DIRECT CENTER SECOND CALENDAR-LUNAR
 VEN 223  DSS-CALENDAR W/DATE HAND & DAY & MONTH DISKS
 VEN 225  DIRECT CENTER SECOND
 VEN 226  DIRECT CENTER SECOND CALENDAR W/DATE HAND ONLY
 VEN 227  DIRECT CENTER SECOND CALENDAR
 VEN 230  DIRECT CENTER SECOND-ALARM
 VEN 231  ALARM-DIRECT CENTER SECOND BM 230
 VEN 232  ALARM-CALENDAR-DIRECT CENTER SECOND BM 230
 VUL 124  AUTOMATIC-DIRECT CENTER SECOND
 WIT 10ES  DIRECT CENTER SECOND-FLAT OR BREGUET
 WIT 11ES  DIRECT CENTER SECOND-FLAT OR BREGUET
 WIT 11ESK  DIRECT CENTER SECOND-KIF SHOCK
 WIT 11RW  AUTOMATIC-DIRECT CENTER SECOND
 WIT 11RWK  AUTOMATIC-DIRECT CENTER SECOND-KIF
 WYL WG28  DIRECT CENTER SECOND-INCAFLEX
 WYL WH222  INCAFLEX DSS
 WYL WH225  DSS-CALENDAR-INCAFLEX
 WYL WH25  AUTOMATIC-INCAFLEX
 WYL WH26  AUTOMATIC-INCAFLEX
 ZOD 1094  DIRECT CENTER SECOND-INCABLOC
 ZOD 10S  DIRECT CENTER SECOND-STOP
 ZOD 1501  DIRECT CENTER SECOND-RESERVE POWER INDICATOR